Color: Red/Black Primary Chamber to include: Fully insulated internal refractory lining. Constructed from high grade refractory brick ensuring a self-supporting interlocking arrangement Fully interlocked, manually operated access door Waste ignition burner, temperature controlled on-off, complete with internal air fans Combustion burner, temperature controlled on-off, complete with internal air fans Secondary combustion burner air fans with automatically controlled distribution to their designated area One temperature sensor mounting point Secondary chamber to include: Fully insulated internal refractory lining. Constructed from high grade refractory brick and low thermal mass insulation. Secondary chamber burnout burner, temperature controlled on-off. Complete with internal air fans. Integrated combustion burner air fans with automatically controlled distribution to their designated area. All combustion fuel pipework All electrical components One temperature sensor mounting point at the base of the exit flue ensuring the chamber reaches the necessary 1100oC minimum Incinerator Dimensions: External - 2988 L x 1114 W x 1821/4161 H (mm) Internal – 1140 L x 700 W x 800 H (mm) Chamber volume – 0.64 M3 Weight – 4 (approx. tonnes) Max load capacity – 256kg Nominal burn rate (kg/hr) - <50 Power supply (50/60hz) – 220-250v Thermal capacity (kW) – 270 Door aperture – 670 x 550 Control Panel – AIC Fuel Types – Diesel, LPG, N-Gas Insulation fire brick – Grade E23 Insulation board – 25mm superwool Fire brick (alumina) – 42.5% Installation & Delivery shall include: CIF to Port DAP – Door to door Lead time anywhere from 10-16 weeks One year warranty Training to be included by the Contractor 1 years’ worth of incidental and consumable spares (gas) Touchscreen control panel and downloadable APP to monitor process on any mobile device. Safe disposal of confiscated narcotics, medicinal drugs and other types of drugs Front loading machine The Agency shall supply on-site lifting equipment