Red Iron Pavilion 50 x 60 x 12 with 4’ overhang on the eve sides and 2’ overhang on the gable end Concrete pad – 60’ x 70’ x 6” Ceilings/Overhang/Roof finished with metal Metal columns to be brick 10’ tall from finished pad 2 - cupola’s Gutter and down spouts sleeved under concrete to outside of concrete pad Wood Pavilion 50 x 60 x 12 with 2’ overhang on a 6/12 pitch with scissor trusses Concrete pad – 60’ x 70’ x 6” Ceilings/Overhangs/ Roof finished with metal Post to be brick 10’ tall from finished pad 2 – cupola’s Gutters and down spouts sleeved under concrete to outside of concrete pad Electrical Installation of a 100-amp, 120/240-volt, single-phase electrical service Adequate energy-efficient LED lighting to provide proper illumination throughout the pavilion Installation of general-use receptacles placed to meet the National Electric Code (NEC) requirements Electric Requirements Bidder must hold a valid electrical contractor’s license in the State of Kentucky All bids shall include a complete itemized scope of work, materials to be furnished, a project schedule, and an ETA of completion of project Bathrooms Men’s and Women’s ADA 50’ x 12’ x 10’ with men and women restrooms and storage room Men’s – toilet, urinal, and sink Women’s – 2 toilets and sink Stall Walls Interior - painted block and metal ceilings Exterior – split face block Waterline and sewage, including lift station 3 – 3’ metal doors 1 – 2’4” metal door 1 – 6’ roll up door