Specifications include, but are not limited to: 1.0 The system shall be designed for “Against-The Wall” installation. The system shall be supplied on a vertical steel frame designed for both the static and dynamic loads of the system and of sufficient size to adequately accommodate all of the system’s components. 1.1 The system shall be supplied in a foam insulated cabinet enclosure for sound attenuation. Radiant sound levels shall be approximately 72 dba within one meter of the compressor. The cabinet enclosure shall incorporate a horizontally hinged, and gas shock supported operations panel. The front access door shall be of the Keyed-tool latch type inhibiting accidental access while the unit is running. Additionally the door shall be equipped with an automatic system shutdown switch in the event someone opens the door while the system is operating. The cabinet side maintenance access doors shall be designed for easy lift off without the use of hand tools. The rear access panel shall incorporate recessed handholds and shall be of the lift off as well. The design of the enclosure shall permit unrestricted cooling air flow to the compressor and prime mover, and provide access for operation, inspection and maintenance. 1.2 The system shall be designed for continuous duty operation indoors with room temperatures ranging between 40°F and 115°F1. Installation shall not require a special foundation; however, it is the responsibility of the purchaser to ensure the installation site has a solid and level foundation that can support the weight of the system as well as the availability of a qualified source of air for the intake of the compressor and adequate ventilation. 1.3 All piping, tubing and high pressure hoses shall be properly supported and protected to prevent damage from vibration during shipment, operation, or maintenance. Piping, tubing and hoses shall be installed in a neat and orderly arrangement, adapting to the contours of the system. All instrument tubing shall be 300 series stainless steel.