Specifications include, but are not limited to: Fabric: 72” 9 GA. Galvanized (2” Mesh) Chain Link Fabric. Top Rail: 1 5/8” O.D. DQ-40 pipe, 1.83 lbs. per foot. Top rail 21’ in length, joined with 1 5/8” sleeve. Line Post: 2 3/8” O.D. DQ-40 pipe, 3.65 lbs. per foot. Line posts set 10’ on center maximum spacing. Concrete footing: 12” diameter, 36” depth. Terminal Post: 4” O.D. DQ-40 pipe, 4.47 lbs. per foot. Concrete footing: 12” diameter, 42” depth. Gates: Single Swing Gate: Framework of 1 7/8” DQ-40 pipe, 2.72 lbs. per foot. Cantilever gate: Framework of 2 3/8” Full Weight pipe, 3.65 lbs. per foot. Gates braced and trussed as necessary. Same fabric as fence. Barbed wire included on all gates. Gate Post: Single swing-gate: 2 7/8” O.D. DQ-40 pipe, 4.47 lbs. per foot. Concrete footing: 12” diameter, 36” depth. Cantilever Gate: 4” O. full weight pipe, 9.10 lbs. per foot. Concrete footing: 12” diameter, 42” depth.