Specifications include, but are not limited to: •Number of Units (8) •Eave height 17' max •clear door opening 44'x14' minimum •individualhangardepth39’minimum.•Total enclosed square footage must be under 12,000. •all steel requires primer coat •Roof 24 ga. (minimum) PBR Galvalume (or equivalent) with 20-year manufacture limited warranty •24 ga. (minimum) PBR Silicone Polyester color finish sheeting exterior walls and hangar doors. Minimum 30-year manufacture warranty •24 ga. (minimum) Galvalume full height interior partition though the hangar to section off each hangar individually •(8) 44'x14' minimum clear opening with electric bi-fold style doors. Door to have 230-volt electric motor, 3 station push button controls (momentary up and down), manual door latches, top/bottom rubber door seals and 4 cable/strap pick up. Include white steel walk-though door with lockset, hinges, trim and hardware. Hangars will conform to below listed building code information (minimum) •15 psf ground snow load, 20 psf roof live load. •Occupancy Category II, Ct thermal factor of 1.2 for unheated building. •Unbalanced snow load provisions as per the ASCE 7-05. o 115 m.p.h. wind speed, Exposure C. o •Structural design based on the design criteria of the IBC 2012.