Specifications include, but are not limited to: BUILDING SPECIFICATIONS: 50'W X 80'L X 16'H (inside) • 50' Pre-engineered Wood Trusses @ 4 / 12 pitch • 1' Overhang with boxed/vented Soffit • Post Hole 4' 6"D X 1' 6"W with Composite Footing Pad or (per engineered plans) • 2x6 SYP uplift protection or (per engineered plans) • 3 ply 2x6 Post (Eaves 8' O.C.) (Gables 10' O.C.) • On Edge 2x4 SYP #2 2' O.C. Roof Purlins • 2' 3" O.C. 2x6 SYP #2 Wall Girts or (per engineered plans) • 2x8 Treated Skirtboard; SIDING AND ROOF: • Roof: Charcoal Gray 26ga Metal Roof Panel w/ 2" Vinyl Backed Insulation • Wall: Charcoal Gray 26ga Metal Wall Panel w/ 2" Vinyl Backed Insulation • Trim: Red 26ga Metal Trim • Approximately 160’ of gutter with down spouts • All metal colors will match as close as possible current building at 5851 10th St, Great Bend; DOOR AND WINDOW DETAIL: • 4 - 12x14 White Overhead Doors - Left of Main Building • 1 - 3-0 9 Lite White Door - LH in Swing - Left end Main Building • 1 - 3-0 9 Lite White Door - RH in Swing – Right end Main Building • OHD Details: 4- 12’w x14’h Insulated Commercial Door; White. to Include Electric Opener with wall controls and 1 Remote/Door; Second/Separate Bid: Approximately 2500 sq ft (30’x80’) 4000 psi, 6” thick concrete with ½” rebar 24”on center both ways placed on chairs, cut and light broom finished, building approach/driveway to be sloped away from building, match up to current driveway and allow for water to drain. Some dirt work will possibly be required.