Specifications include, but are not limited to: new installation of armored 12 strand OSP fiber cable through new 2” HDPE conduit along 4th Avenue NE in Sioux Center, IA. New conduit will run from existing Dordt College handhole at 5th St NE to an existing AEA building handhole north of 12th St NE. Approximately 3924’ of new duct and four new 24x36x36 handholes will be required to connect the existing building handholes. The HDPE conduit shall be no less than 48 inches deep in all areas. A 12 strand armored cable will be pulled in from the AEA building to the new handhole at the corner of 4th Ave NE and 5th St NE. At this handhole a splice closure and Iso-lever locate station will be installed and a 12 strand dielectric indoor/outdoor cable will be pulled into the Dordt College Ribbens Center Building. Restore right of way and remove any debris from the construction area upon completion.