Specifications include, but are not limited to: 01 Install a Panasonic exhaust fan with a three‐speed DC fan ((50,80,110), or variable speed) or approved equal, and vent to the exterior of the house with solid insulated pipe. Install with a humidity sensor (extra from manufacture). Install on lowest speed or as needed for the size of the house. Install at a central location and exhaust out the right side of the house. Install to manufactures installation requirements. ________________ 02 Remove the flooring along the perimeter walls: rear, entire right wall and the left wall from the wood wall to the back corner. Remove the soil to about 12 inches deep and install socked 3‐inch drain tile to be discharged in to the sump pit. Fill area around the tile with clean gravel, then cover with concrete to floor level.