Specifications include, but are not limited to: Basement: Remove paneling from the walls and dispose. Remove any framing that is water damaged and dispose; Remove loose parge coating and mortar. Tuck point all walls as needed; Install a 30-inch-deep by sump jar with an airtight seal, with drain and viewing window. Install in the low spot of the basement. Over dig the jar hole by about 6 inches all the way around the new sumps. Fill the area around the sump jar and around the tile with clean gravel. Drill ½ holes in the sump jar to allow water in. Start the holes about 15 inches above the bottom; Main Floor: Install one Kidde Carbon Monoxide alarm with a 10-year sealed battery C3010, or equal. Install in the lowest habitable level, finished room, about four feet above the floor in an open location. Secure detector to wall with manufacturer supplied bracket in accordance with manufacturer’s instructions. If you need location clarification, ask for guidance. This detector is not hardwired.