Mesh Panels 4.6.1.1 Material - Industrial-Grade, hot-rolled steel wire. 4.6.1.2 Wire Gauge - Minimum 10 Gauge Steel (#6 gauge when required). 4.6.1.3 Mesh Opening - Maximum 2”x2” rectangular pattern welded at intersections. 4.6.1.4 Panel Construction – Fully welded construction; framed within 1-1/4” x 1- 1/4” steel angle. 4.6.1.5 Height – Panels must be available in standard heights (8’, 10’, 12’ nominal) and capable of ceiling attachment if required. 4.6.2 Posts and Framing 4.6.2.1 Posts – Minimum 2” x 2” structural steel tube posts, pre-punched for hardware. 4.6.2.2 Base Plates – Minimum 4” x 4” steel base plate, securely welded to the post. 4.6.2.3 Anchoring – Posts must be anchored to concrete floors using minimum 3/8” diameter tamper-resistant expansion anchors (e.g., wedge anchors, security bolts) 4.6.3 Doors and Locking Mechanisms 4.6.3.1 Door Type – Single or Bi-Parting Sliding Doors (Swing doors may be considered if required by site limitations. 4.6.3.2 Construction – Same gauge mesh and framing as standard panels; reinforced corner braces. 4.6.3.3 Tracking System – Heavy-duty steel track and roller system ensuring smooth operation and resistance to derailing, fully enclosed to prevent access to rollers.