SMOKE DETECTORS. On each level of the dwelling unit including basements, but excluding crawl spaces and unfinished attics at least one wireless battery?operated or hard?wired approved smoke detector in proper operating condition must be present. All smoke detectors are to be replaced. BATTERIES MUST BE 10 YEAR TYPE. Smoke detectors must be installed in accordance with and meet the requirements of the National Fire Protection Association Standards (NFPA) 74 or its successor standards. If a hearing?impaired person is occupying the dwelling unit, the smoke detectors must have an alarm system designed for hearing?impaired persons as specified in NFPA 74. Smoke detectors shall be located as follows (IAC 661.210.3(11) : On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. In each room used for sleeping purposes. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. To include combination smoke/carbon monoxide detectors where required per City code. OUTLETS: Replace 2 prong outlets with GFCI or grounded outlet. All work performed under NEC and IRC Codes. Location: ENIRE HOUSE GFCI OUTLET/S: Replace existing outlets within 6' of a water source with GFCI protected duplexes per code. All wiring must be concealed and installed under NEC and IRC codes. Location: KITCHEN REPLACE NON-FUNCTIONING WINDOW/S ( 2 EACH ): Replace window with double hung insert or new construction with full screen. Remove existing storm windows, if any. Remove the existing windows. Install new vinyl windows with thermal pane and removable sash. Window must be LoE, argon filled with welded corners. Install according to manufacturer's recommendations. Properly fill gap between window jam and existing window frame with expanding foam or fiberglass insulation (if applicable). Re install trim if in good condition or provide and install new trim finished to match. Caulk exterior. Install as per IRC codes. Lead safe practices required. Approximate Size: (contractor measure) Location: DINING ROOM - 2 SOUTH REPLACE NON-FUNCTIONING WINDOW/S ( 3 EACH ): REMOVE PICTURE WINDOW AND FRAME FOR 3 DOUBLE HUNG WINDOWS. Replace window with double hung insert or new construction with full screen. Remove existing storm windows, if any. Remove the existing windows. Install new vinyl windows with thermal pane and removable sash. Window must be LoE, argon filled with welded corners. Install according to manufacturer's recommendations. Properly fill gap between window jam and existing window frame with expanding foam or fiberglass insulation (if applicable). Re install trim if in good condition or provide and install new trim finished to match. Caulk exterior. Install as per IRC codes. Lead safe practices required. Approximate Size: (contractor measure) **REMOVE PICTURE WINDOW** Location: MASTER BEDOOM - 3 NORTH