Specifications include, but are not limited to: Exterior; Dispose of original and replace 208' with 6 ", K Type,seamless,.027 aluminum gutter to first and second stories. Install 208' of gutter guards to gutters on first and second stories. Install 90' of downspouts to match (3"X5"), concrete splash blocks and accessories to service entire dwelling. Install downspouts at each corner and major offest with hidden hanfers 3' on center.Color choice by owner.Report defective fascia and apply for change order. Downspouts not to discharge onto roof surface. Install a UL approved, ceiling mounted, battery powered smoke and fire/ co detector and battery in accordance with 2021 International Residential Code. Dispose of 30 year old furnace in legal dump. Install an intermittent pilot, gas fire, forced air furnace with minimum AFUE rating of 86 to existing plenum and gas line. Include set back thermostat, flue pipe and shut- off valve. Size furnace per heat loss analysis. All new installtions will include alluminum flex chimney liners. HVAC PERMIT IS REQUIRED. Remove the 20 year old water heater. Dispose of old water heater in code legal dump. Install a 50 gallon, glass lined, high recovery, insulated to R-7, gas water heather with a 10 year warranty. Replace shut-off valve. Include pressure and temperature relief valve, discharge tube to within 6" of floor or to outside of structure, vent, thimble, and gas piping from newly installed shut-off valve to fixture. Front Entry Hall; Repair deteriorating first step and newel post for safety. Remove and repair unstable separating newel post. Remove and repair first step which is separated from the landing. Tighten loos balusters and existing handrail. Secure stair nosing. Match existing parts with replacements as closely as possible. Install a UL approved, ceiling mounted, battery powered smoke and fire/ co detector and battery in accordance with 2021 International Residential Code. Kitchen; Install a UL approved, ceiling mounted, battery powered smoke and fire/ co detector and battery in accordance with 2021 International Residential Code. 2nd Floor Hall; Install a UL approved, ceiling mounted, battery powered smoke and fire/ co detector and battery in accordance with 2021 International Residential Code. 3 Upstairs Bedrooms; Install a UL approved, ceiling mounted, battery powered smoke and fire/ co detector and battery in accordance with 2021 International Residential Code. 3 EA