Specifications include, but are not limited to: This bid is for construction of three (3) houses. 1. Each home must meet the State of Georgia “Visitability Requirements “of O.C.G.A 8-3- 172. These include: • No step entry through a 36” in. door. • Each interior door is at least a standard 32-inch door, unless the door provides access only to a closet of less than 15 square feet in area. • Each hallway has a width of at least 36 inches and is level with ramped or bevel changes at each door threshold. • Each bathroom wall is reinforced for potential installation of grab bars. • Each electrical panel or breaker box (located on the first floor), light switch or thermostat is not higher than 48 inches above the floor. • Each electric plus or other receptacle is at least 15 inches above the floor