Specifications include, but are not limited to: NEW OFFICE:•Include 1 separate move-in. •Install carpet tiles over the existing VCT in the new office, per the manufacturers recommended procedures. Terminate carpet tile under the door of then office.•Use specified adhesive for excessive moisture.•Install layout pattern similar to existing in other offices nearby.•Furnish and install black transition strip below doors, similar to existing offices nearby.•Furnish and install Johnsonite, 4” rubber wall base, 168 Thunder, to match existing, per the manufacturers recommended procedures.Carpet Tile:Style: 4298R PresidentialColor: N627B Washington Size: 24”x 24” Tiles•Repair/patch drywall surfaces•Paint all walls from corner to corner with Sherwin Williams Super Paint, SW 6149 Relaxed Khaki, eggshell finish, (2 coats).•Provide a new circuit for power receptacles as required per code (4 duplex receptacles minimum, 1 at each wall). All circuitry shall have a minimum 20amp capacity, minimum 12 gage wire).•Provide 2 new data drops at one wall, (location as directed by owner in the field).•Replace light fixtures with LED bulbs with equivalent lumen replacement.•Obtain permitting and inspection approvals as required (Forsyth County permit fees waived).