Specifications include, but are not limited to: 4.5.1 Wire rope: 8:1, versus minimum breaking strength as reported by the manufacturer. 4.5.2 Sheave diameter: As recommended by rope or wire rope manufacturer. 4.5.3 Maximum fleet angle: 1.5 degrees (maximum), or per manufacturer’s specific recommendation(s).10 4.5.4 Terminating hardware: 5:1, or not exceeding published WLL, whichever is more restrictive. 4.5.5 Purchase lines: Minimum tensile strength of 21,600N (4,860 pounds), when new. 4.5.6 Trim chain assembly and turnbuckles: 5:1, or not exceeding published WLL, whichever is more restrictive. 4.5.7 Batten clamps: 5:1, or not exceeding published WLL, whichever is more restrictive. 4.5.8 Fiber Rope lifting lines: 10:1, 3/4 inch minimum diameter.