CGC Walnut doors and scuttles
RDD: 1/13/2026
Please see SOW in attachments
Consolidated List of References
The below-listed documents form a part of this specification to the extent specified herein. Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.
All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.
COAST GUARD DRAWINGS
Coast Guard Drawing 225 WLM 167-001, Rev W, 1997, Structural Closures
Coast Guard Drawing 225 WLM 631-002, Rev B, 2019, Paint Schedule
COAST GUARD PUBLICATIONS
Coast Guard Commandant Instruction (COMDTINST) M10360.3, Jun 2006, Coatings and Colors Manual
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures
OTHER REFERENCES
Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health Standards for Shipyard Employment
Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting
Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning
NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure
The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal
The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning
- ITEM 1: Fabrication of Watertight Door and Scuttle
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to fabricate watertight doors, hatches, and scuttles identified in Table 1 in accordance with drawings and references.
Table 1 - Watertight Doors and Scuttle locations
Description
Location
P/N and Description
QTY
Drawing
Weathertight Door (01-27-1)
01-26-0-C Buoy Deck Control Booth
PN: 20
Weathertight Steel Door 26”x66”, Right Hand, w/ hasp and staple
01 Each
225 WLM 167-001
Raised Watertight Quick Acting Scuttle (01-20-2)
Escape Trunk
(1-19-2-T)
PN: 6
Scuttle – 21” Dia C.O. Raised, Quick-acting, Watertight
01 Each
225 WLM 167-001
1.2 Government-furnished property
None
2. REFERENCES
Coast Guard Drawings
Coast Guard Drawing 225 WLM 167-001, Rev W, 1997, Structural Closures
Coast Guard Drawing 225 WLM 631-002, Rev B, 2019, Paint Schedule
Coast Guard Publications
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures
Other References
Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting
Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning
The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning
The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal
3. REQUIREMENTS
3.1 General.
3.1.1 CIR.
None.
3.1.2 Tech Rep.
Not applicable.
3.1.3 Protective measures. Not Applicable
3.1.4 Interferences. Not Applicable
3.1.5 Fabrication. Contractor shall fabricate the door and scuttle listed in Table 1 and in accordance with the references listed in section 2 of this document.
3.1.6 Testing. All testing to be completed in accordance with drawings and Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes.
3.1.7 Shipping. Contractor shall construct container to ship doors and hatches and must include pricing for shipping to CGC WALNUT, CO LTJG Daniel Zarillo, USCGC WALNUT (WLB 205), 211 South Ave Suite C, Pensacola, FL, 32508.
4. NOTES
None.