A. Work covered by this section of the specifications shall conform to the contract documents, engineering plans as well as state and local codes. B. The purpose of these specifications is to define the lighting system performance and design standards for Newark Schools Stadium using an LED Lighting source. The manufacturer / contractor shall supply lighting equipment to meet or exceed the standards set forth in these specifications. C. Contractor is responsible to remove and properly dispose of existing luminaires and electrical enclosures. D. The sports lighting will be for the following venues: 1. Football 2. Home Bleachers 3. Away Bleachers D. The primary goals of this sports lighting project are: 1. Lighting Design Upgrade – Upgrade light levels and uniformity on the field by replacing existing HID luminaires with LED luminaires to achieve original design light levels. a. Guaranteed Light Levels: Selection of appropriate light levels impact the safety of the players and the enjoyment of spectators. Therefore, light levels are guaranteed to not drop below specified target values for a period of 10 years. b. Environmental Light Control: It is the primary goal of this project to minimize spill light to adjoining properties and glare to the players, spectators and neighbors. 2. Control and Monitoring – To allow for optimized use of labor resources and avoid unneeded operation of the facility, customer requires a remote on/off control system for the lighting system. Fields should be proactively monitored to detect luminaire outages over a 10-year life cycle. All communication and monitoring costs for 10-year period shall be included in the bid. a. Control and monitoring system shall provide contactor control of all existing circuits, replacing existing contactor cabinets. Key switches shall be provided to provide field-level control of existing circuit groups.