All work shall be performed in strict accordance to the contract documents and shall include, but not be specifically limited to, the following: • Any and all damage to the surrounding area must be repaired; • Contractor to include protection of work site (i.e. barricades, caution tape, windscreen, lock for gate(s) etc.); • The structures must meet all current Volusia County and Florida Building and Fire Codes with a minimum wind rating of 160mph and meet Florida Building Code (FBC), which is based on the American Society of Civil Engineers (ASCE) standard; • The buildings must be Americans with Disabilities Act (ADA)-compliant and meet any applicable Florida architectural accessibility standards. Modular fabrication and installation shall meet or exceed all Modular Building Institute (MBI) standards for Office Modular Buildings, and Americans with Disabilities Act (ADA). • The provision of all necessary Volusia County requirements – related Notices of Approval (NOA’s) and all required building permits and testing; • The Contractor shall be responsible for obtaining and coordinating the marking of all subsurface utility elements – line locations, vaults, and the like – by an experienced, qualified, private line location company, and by Sunshine State Line Locations. Any damage to any sub-surface elements shall be the sole responsibility of the Contractor, and the Contractor shall bear all costs of required repair and/or replacement; • Site must be left in “ready” for use conditions; • Warranty and Guarantee: Proposal shall include the warranty and guarantee associated with the labor and materials. Minimum requirements include three (3) year on material, and labor; • The building project shall follow all applicable federal, state and local building codes, laws, ordinances, rules and regulations; • Final inspection, issuance of certificate of occupancy, and approval by the City’s Public Works Representative prior to final payment. • The City will be responsible for water, sewer and electrical utilities to the sites; LOTS # 1 & # 2 - NEW or USED Modular Office Building The modular building shall meet, exceed or be similar to the following specifications: Building Size: Thirty-feet (30’) x sixty feet (60’), 1,800 sq.ft., or similar size Floor Structure: Steel Frame with two inch (2”) x eight inch (8”) wood joists and plywood floor decking Floor finish: Vinyl Composite Tile throughout Exterior walls: Wood stud, sheathing as required, and finished on the outside with Hardie Panel siding, or substantially similar alternative (concrete board) Rooms: Six (6) office spaces, with one as a storage room for lockers, two (2) restrooms (One (1) ADA with ADA shower), one (1) breakroom, Exterior Trim: Hardie Trim, or substantially similar alternative Windows: Eight (8) or nine (9), thirty-six inch (36”) x sixty inch (60”) impact rated white vinyl frame vertical slide insulated (low E glass) Windows with Vinyl Mini-blinds Doors: Two (2) thirty-six inch (36”) x eighty inch (80”) impact rated steel/steel exterior door with view block, door hardware and deadlocks. Eight (8) or nine (9), thirty-six inch (36”) x eighty inch (80”) pre-hung woodgrain finish interior doors with steel frame. Roof: White Ethylene Propylene Diene Monomer (EPDM) Rubber Roof installed per Florida Building Code (Volusia County) HVAC System: The HVAC system shall consist of the required number of 2-ton, wall-hung air conditioning units. Each unit will include fiberglass supply ducts and ducted return air systems. The installation shall also include thermostats, supply diffusers, and return air grilles as necessary for proper operation and distribution. Interior walls: The interior walls will be constructed with wood studs, insulated and finished with prefinished vinyl covered gypsum drywall. Trim package to be standard and four inch (4”) vinyl cove base throughout. Ceiling: Prefinished @ eight feet (8’) above floor. Electric: To consist of a two hundred (200) amp single phase electrical panel. Exhaust fan in bathrooms. 2/40 diffused fluorescent lighting and LED porch lights. Outlets located on all walls, approximately ten (10) empty j boxes to be included. J boxes shall be stubbed thru the floor unless otherwise instructed. Location of j boxes may be designated by the City. In addition, the City requires junction boxes to provide hookup for camera/security system. Plumbing: Building to include two (2) bathrooms, one (1) standard commode, one (1) ADA commode, one (1) ADA shower, two (2) wall mount lavatories, two (2) mirrors, with stainless steel kitchen sink and faucet in breakroom, and an instantaneous water heater. Cabinets: Up to ten (10) linear feet of oak base and overhead cabinets in breakroom. Steps: Aluminum steps with 5’x5’ landing, handrails tied down pursuant to local building code. Ramp: Include as an alternate, a ramp to meet ADA requirements, for access to the modular building. Installation: The building shall be installed on a foundation that meets Florida Building Code (whether that is dry-stack block foundation or solid concrete foundation) utilizing above grade pads and hurricane ground anchors to comply with Florida Building Code (Volusia County). Foundation design assumes 2500 PSF soil bearing capacity. Finished floor elevation shall be no less than forty inches (40”) above grade. Anchors and hardware shall all be galvanized to delay corrosion. Skirting: Use of PVC lattice or substantially similar alternative.