Specifications include, but are not limited to: Complete reformatting and upgrading of all occupied spaces, including offices, class room, open areas, break room and restrooms; includes finishes, furniture and fixtures. Restrooms need to be expanded and upgraded to meet current ADA requirements for access. Construction of new support and storage spaces, including server room, copy room, and closets/lockable storage. Upgrade of all operating systems (HVAC, plumbing, electrical) and related fixtures (toilets, sinks, light fixtures, etc.) HVAC work includes controls; plumbing includes supply and drain/waste/vent lines. Upgrade of warehouse doors and storefront systems to Miami-Dade standards. Upgrade of locksets, keying systems, and card access to building entrances, exits, and gates. Upgrade with new guard shack built to JEA generating station requirements which includes multiple access controlled gates, gate arms, lanes of entrance and exit, and network fiber optic