Specifications include, but are not limited to: 1 Mobilization 1 LS 2 Maintenance of Traffic 1 LS 3 Preconstruction Audio/Video Recording 1 LS 4 Survey and Record Drawings 1 LS PART 2: IRRIGATION MAIN ITEM NO. DESCRIPTION EST. QUANT. UNIT UNIT PRICE EXTENDED PRICE 5 Furnish and Install IQ Main a. 12" PVC 64 LF b. 24" HDPE - DR11 3,143 LF 6 Connect to Existing Main a. Connect to Existing 12” 3 EA b. Connect to Existing 20” 1 EA c. Connect to Existing 42” 1 EA 7 Furnish and Install Valves a. 12" Gate Valve 4 EA b. 12" Gate Valves (for Motor Operation) 2 EA c. 20" Gate Valve 1 EA d. 24" Gate Valve 9 EA 8 Horizontal Directional Drills - (24" HDPE DR11) a. Under Detention Pond (561 LF) 1 LS b. Under Creekside St (STA 3+74 to STA 7+54) (384 LF) 1 LS c. Under Creekside St (STA 10+83 to STA 14+94) (410 LF) 1 LS d. Under Immokalee Road (393 LF) 1 LS 9 Air Release Valves 9 EA 10 Above Ground Piping and Pipe Stands 1 LS