Specifications include, but are not limited to: f alteration of the perimeter of the existing library to provide and install permanent glass flood barriers (storefront system), a pedestrian flood door, and a waterproof epoxy coating with a paint topcoat adjacent to the flood control systems as required.. The work includes but is not limited to: a. Doors and windows included in this project are W6, W10, W11, and D18 as indicated on the drawings. b. Scope of work is summarized below and further detailed on drawings: 1) The Contractor shall provide for electrical work required for the project including but not limited to the following: Removal and reconnection/relocation of access control hardware, disconnection and reconnection of alarm systems, disconnection reinstallation/relocation of power outlets, and extension of power and data to the new flood control assemblies, engineering, permitting and material testing, and ADA door operator and controls. 2) Contractor shall also provide for the flood door testing indicated in the contract documents (drawings and specifications). 3) SECTION 02 41 00 DEMOLITION: Selective demolition and Removal of existing storefront assemblies, doors, and frames and preparation of rough openings for installation of new permanent flood barriers. Salvage, Removal and replacement of access control devices. Selective Demolition of walls, ceilings and flooring as required to accommodate new construction. Installation of new walls, ceilings and flooring adjacent to new permanent flood barriers and related appurtenances as required. The project also includes the demolition of a coiling door assembly and installation of a pedestrian flood door assembly at the removed coiling door location. 4) SECTION 03 30 00 CAST IN PLACE CONCRETE: Repair of precast concrete panels, reinforced concrete masonry walls, sidewalks, and related appurtenances damaged by selective demolition construction work. also includes new formed concrete work as may be required to prepare rough openings for new flood barrier assemblies. 5) SECTION 07 16 13 EPOXY WATERPROOFER: Clear two-part 100% solids, thermo setting, self-curing epoxy coating with sand texture finish. Coating shall harden to a ceramic like, clear, non-porous waterproof film for use on exterior concrete, precast concrete, stucco, metal, and similar surfaces. Provide and install epoxy water proofing as required adjacent to the new permanent glass flood barriers (storefront system). 6) SECTION 07 9100 JOINT SEALANTS: Provide and install sealant and caulk at new glass flood barriers systems. Replacement of existing joint sealants and caulks where disturbed by new construction. 7) SECTION 08 71 16 AUTOMATIC DOOR OPERATORS: Low energy automatic swing door operator for use in handicap applications including aluminum guide rails, aluminum operator housing, electro-mechanical motor, operator assembly, swing arm and electronic controls. Electrical outlets and the extension of power to the new automatic door operator 8) SECTION 08 39 18 PERMANENT GLASS FLOOD BARRIERS: Aluminum-Framed Storefront Flood Mitigating Entrances for exterior storefront locations as indicated on drawings. Flood barrier system Engineering required to meet the specified flood requirements is included as part of this section. Contractor shall provide and install new door hardware. Contractor also shall provide rewire/ reconnection/relocation of access control devices to the new permanent glass flood barriers and power.