Specifications include, but are not limited to: Use Belden's 10GXW28 10GXS12 cable for all data transmission. Use solid copper conductors for all cable runs. Use a minimum of 23 AWG conductors for horizontal cable runs. Use a minimum of 24 AWG conductors for patch cord cable runs. Install cable in a conduit where possible. Use plenum-rated cable for any runs through air handling spaces. Use a minimum of Category 6a compliant outlets. Follow TIA/EIA 568-B.2 standards for termination and testing. Use Belden's AX103115 GigaBIX Termination Tool for field termination of the connectors. Perform a continuity test on all copper and fiber cabling using a Fluke DSX-5000 CableAnalyzer. Certify all cabling to Category 6a performance standards using a Fluke DSX5000 Cable Analyzer. Fiber lines will need to be added from each server room into the existing Bay County courthouse. Clerk of Court will need one 12 pair. Room 107 into the courthouse first floor server room (Verify with Court Technology for more information as location may change as ongoing work is completed) Court will need two 12 pair lines. First Run: Room107 into the Circuit Server Room. Second: Room 107 into the 2nd Floor Server Room. (Verify with Court Technology for more information as location may change as ongoing work is completed) Access Control will be provided by owner. Security cameras will be provided by owner. o Mounting will be performed by vendor. (63 Interior, 17 Exterior, and 4 holding cell) Access points will be provided by owner. o Mounting will be performed by vendor. Fiber shall be indoor and use LC Core Align Fusion Splices. (No substitutions) All racks will be Belden 4 post open frame.