Specifications include, but are not limited to: · Two one-story additions to the existing school building. One addition will be located on the south side of the school and will consist of classroom areas with footprints of approximately 290 feet by 100 feet. The second addition will be located on the east side of the school and will be a multi-purpose room with a footprint on the order of approximately 70 feet by 100 feet; · The buildings are proposed to be constructed at-grade (i.e., no basement) with assumed finished floor elevation that will match that of the existing building (i.e., net cuts/fills of less than 2 feet will be required to achieve finish grades); · At the time of this report, structural information for the proposed additions was not provided. We have assumed structural loads consisting of maximum wall loads of 3 kips per foot and maximum column loads of 100 kips; and · In addition to the building construction, we understand it is proposed to rehabilitate the parking lot area located north of the school.