Specifications include, but are not limited to: Install cameras level and plumb. Coordinate first paragraph below with Drawings. Install cameras with 84-inch minimum clear space below cameras and their mountings. Change type of mounting to achieve required clearance. Set pan unit and pan-and-tilt unit stops to suit final camera position and to obtain the field of view required for camera. Connect all controls and alarms and adjust. Install power supplies and other auxiliary components within the Telecommunication Room unless otherwise indicated. Retain first paragraph below if not indicated on Drawings, or coordinate with Drawings, schedules, and other Sections. Indicate which components are to be fitted with tamper switches and which Section covers tamper-switch connection. Install tamper switches on components indicated to receive tamper switches, arranged to detect unauthorized entry into system-component enclosures and mounted in self-protected, inconspicuous positions. Identify system components, wiring, cabling, and terminals according to industry standards.