Specifications include, but are not limited to: 1. For cost comparison, please address the two scenarios separately: (A) retrofitting the current CD80 rack system to replace the AE processor controls and related components with a Strand Lighting C21 system and (B) replacing the CD80 rack system entirely with a recommended solution. 2. For an upgrade to a Strand Lighting C21 system, please include the following: (1) All AC to DC power supplies and cooling hardware shall be replaced; (2) The second rack has 6 unoccupied dimmer module slots not connected to the grid. The slots do not allow a dimmer module to be inserted and should be repaired. They should be connected back to the main control processor for possible future expansion; (3) A CD80 Dimmer Test Module that provides voltage taps and status indication for the two channels; (4) Repair any rack hardware that is damaged or missing; (5) thorough cleaning of the rack interior. 3. The solutions should address any improvements necessary to meet updated Federal, State and Local code requirements related to the scope of this project. 4. The solutions should make use of existing incandescent luminaries on the grid. 5. The solutions should provide the ability to connect existing and future LED luminaries to dimmer circuits on the grid. 6. The solutions should provide dimmer circuits for the existing apron and house recess lights that can accommodate LED light bulbs. 7. The solutions should allow easy integration with upstream and downstream devices connected on the DMX communication network. 8. The solutions should provide ability to “sweep” the status of all dimmers at a set time and day of week to turn off channels that have been left on. Or the integration of occupancy sensors to turn off all channels after a defined period of inactivity. 9. The solutions should include the replacement of existing analog DMX control stations at two locations to provide basic, pre-set lighting controls that are programmable by personnel and work independent from the light board. The controls should provide basic dimming and pre-set capabilities that may be required for non-theatrical presentations such as lectures or presentations. Three additional on/off stations are desired at the stage left exit hallway door and the two main exits at the rear of the auditorium. 10. The solutions should include an optional purchase for an upgraded light board that would improve programming of LED luminaries.