Specifications include, but are not limited to: Two (2) Lennox Land Mark series, or equivalent, package units. (4 ton air conditioners and120,000 BTU ‘minimum’ heat) Powered fresh air hoods and relief damper. Both thermostats will be located in the coach’s office with a remote sensor in the clubhouse. •All of the duct work outdoors will be lined with insulation •All of the supply duct work indoors will be wrapped with 1.5” FSK duct wrap •Flex duct work will be rate for R-6 insulation •Registers will be Shoemaker, or equivalent, and of commercial grade •Return air duct will be sealed but uninsulated and terminate at the return grills •The exhaust system will consist of five fans ducted and terminated through the roof •Fans will be Panasonic Whisper Green, or equivalent •Restroom fans will be equipped with Smart action motion sensors •The shower room will be equipped with a condensation module to operate when moisture is detected in the air •All sheet metal work will comply with SMACNA standards •Fans and equipment will comply with the IMC codes as well as the IECC code •*OPTIONAL – Rinnai Demand duo commercial water heater, or equivalent