Specifications include, but are not limited to: 1. Cured-in-place-pipe (CIPP) lining rehabilitation of 156 +/- feet of 8-inch sanitary sewer main, 131 +/- feet of 10-inch sanitary sewer main, 327 +/- feet of 12-inch sanitary sewer main, 997 +/- feet of 15-inch sanitary sewer main, 281 +/- feet of 18-inch sanitary sewer main, 1616 +/- feet of 24-inch sanitary sewer main, and 850 +/- feet of 30-inch sanitary sewer main. 2. Pipe Bursting replacement of 295 +/- feet of 6-inch sanitary sewer with 8-inch with new 8-inch HDPE sanitary sewer main and 442 +/- feet of 8-inch sanitary sewer with new 8-inch HDPE sanitary sewer main. 3. Point repairs to 6-inch, 8-inch, and 15-inch existing sanitary sewer mains. 4. Infiltration Grout repairs at joints on existing 15-inch, 18-inch, 24-inch and 42-inch VCP and RCP sanitary sewer mains. 5. 21 +/- sanitary sewer lateral reconnections. 6. Connection to existing sanitary sewer manholes and modification of existing manhole channels and bases as indicated on the Plans. 7. Sanitary sewer bypassing.