A. Provide magnetic door contacts at locations shown on drawings. Door contacts shall be 3/4-inch diameter designated for steel doors, constructed in plastic including a snapin bushing, and UL approved. B. Provide motion sensors at locations shown on drawings. Motion sensors shall be passive infrared with wide angle coverage. INSTALLATION A. The installation and connections of conductors to equipment, devices, and components of the system by persons qualifies, and experienced in such work. Supervise the installation and connection of equipment, devices and components of the system with a representative of the manufacturer; the representative may be either an employee of the manufacturer or an agent of the manufacturer. The manufacturer’s agent shall maintain a staff of specialists for assistance, installation and maintenance of the particular type of system specified for at least three years. B. Provide wiring required for thin installation of a complete system. Color code throughout and test between conductors. C. Mount central control panel on the plywood backboard in the main telecommunications equipment room. D. Connect intrusion detection system to monitoring company or agency as directed by Owner. E. Secure door Contacts to door frames with adhesive to insure contacts remain securely in place...