The fountain is automated and uses an Ultraviolet Filter, sensors, and probes to maintain healthy sanitation levels and keep the fountain compliant with San Joaquin County Health Code requirements. There is a bromine feeder and 3 sand tanks needing daily checks when the system is operational. The system requires the use of Bromine tablets in the automatic feeder. Chlorine is not allowed to be used with this system; furthermore, no chemicals will be allowed to be stored in the fountain pump/filtration building (utility building). The sand tanks need backwashing after a rise of 8 pounds per square inch. Currently, the clean system runs with a pressure of 12 pounds per square inch. The contractor shall maintain all records and logs required by these Special Provisions, the Regulations, and the Public Pool Standards. All updated logs shall be provided to the Contract Administrator with each pay application request. The contractor shall provide all labor, materials, chemicals, tools, and supplies including all chemicals and testing materials, equipment, and transportation necessary to provide services described in these special provisions.