1. Design Phase: a. Field verify and update as-built drawings. b. Perform an ADA analysis to evaluate and address path-of-travel and plumbing fixture compliance within the scope of the project. c. Provide a design to replace the roof covering and accessories. d. Provide 60% Design Submittal incorporating the field investigation findings, and stakeholder feedback. e. Provide 100% Design submittal to include drawings, book specifications, and a cost estimate. f. The design includes the following: 1. Roof covering and accessories. 2. Roof framing structural repairs to include some roof rafters and rafter tails. 3. Interior renovations to include restroom renovations, some door replacements, and interior finishes. 4. Electrical design to replace some aging panelboards. 5. Electrical design to replace damaged lighting. 6. Electrical design for telecommunication infrastructure such as conduits, pathways, power to data equipment, etc. Telecommunication cabling, such as CAT 6, fiber, speakers, etc. will be by others. 7. Fire alarm design (deferred submittal). 8. Fire sprinkler design (deferred submittal). 9. HVAC duct design. 2. Authority Having Jurisdiction (AHJ) Submittal: a. Submit design documents to the Office of the State Fire Marshal (OSFM) for review and approval. b. Prepare and submit design documents to the Division of the State Architect (DSA) to address regulatory requirements. 3. Construction Administration Services: a. Respond to pre-bid site walk questions. b. Attend virtual construction meetings. c. Assist and respond to bid RFIs. d. Attend construction meetings. Limited to 6 months. e. Review submittals/shop drawings/cut sheets. f. Respond to RFIs. g. Attend punch list site walks, (estimated 3). h. Provide as-constructed record drawings capturing red-line and markups received by the general contractor at the end of construction. B. DELIVERABLES 1. Drawings at 60%, 90%, and AHJ submittals. 2. Cost estimate at 90%, and AHJ submittals. 3. Book specifications at 90% and AHJ submittals