A. Demo work 1. Remove and dispose of all existing old safety devices at all six bay door locations 2. Remove and dispose of all existing old control stations at all six bay door locations B. Bay #1: 1. Remove and dispose non-operational (NONOP) door motor 2. Furnish and install a new 1 HP door motor to replace existing NONOP motor with like or better and to match existing configuration as much as possible 3. Perform function check of roll up door motor and safety systems to confirm proper operation C. Service all six bays roll up door curtains to ensure proper operation to include: 1. Adjust and tighten all items related to the Tensioning devices on both ends of all roll up door curtains 2. Adjust, tightening and lubricate all gear chains connecting door curtain and door motor 3. Service existing door motor to ensure proper operation of Field Adjustable Built-in Functions 4. Lubricate all door rails D. Furnish and install new safety devices with like or better to match existing configuration as much as possible for all six bays roll up doors which include the following: 1. New Photos eyes 2. New Wireless obstruction sensing devices 3. New Anti-entrapment /safety devices. E. Furnish and install new door opener push open/close/stop button control stations with like or better to match existing configuration as much as possible at six bays roll up door curtains. F. Perform function check of all six bays roll up door curtains, motors and safety systems to ensure proper operation. G. All work shall be performed and accomplished in accordance with all current Local, State and Federal building codes and regulations, attached detail drawings and specifications contained herein. H. Clean up area and remove all construction debris from site