Specifications include, but are not limited to: Tenant improvement project to convert Room 126 (approximately 280SF) into (2) separate exam rooms, Rooms 126A and 126B. Demo work: Demo and dispose of existing cabinetry, sink and plumbing Demo and dispose of existing carpet and base Demo and dispose of existing one‐way window Construction: Replace removed one‐way window area with wall framed wall New wall to divide space into (2) rooms Cut‐in for new corridor door at entry into room 126B New wall with door opening in Corridor 130 o Possible relocation of adjacent sprinkler head (TBD) Reconfigure plumbing (supply and waste) for new sinks at each room Add return air register and ducting at new room 126B Split supply air and floor registers to serve each room New vanity and upper cabinet at each room (spec TBD) New sink and faucet at each room (spec TBD) Electrical revisions (outlets and lighting controls) per pending electrical plan Fire alarm modifications TBD Egress signage (TBD) Doors: New corridor door (match existing) at entry to room 126B New cross corridor door and wall at Corridor 130 o Door to match existing corridor doors o Door to be access controlled as follows: Card reader at entry Delayed access with exit alarm at egress Card reader to deactivate exit alarm Required door signage (TBD) Retrofit (E) exterior door (Room 126A) with blank hardware Finishes: New paint at both rooms – low VOC, color to match existing New flooring – Marmoleum sheet vinyl, (color TBD) New Base – 4” Burke rubber wall base (color TBD) Not in Scope: Phone and Data cabling by others (locations TBD)