Specifications include, but are not limited to: Abandoned Well Plugging – Jones #1 – Finney Co. Kansas Corporation Commission (KCC) is seeking a general contractor (hereafter “Contractor”) for a well plugging / site restoration program for one (1) well on the Jones #1 Project in Finney County, Kansas. Bids submitted will be based on rates for various labor, equipment, goods and services to be provided either by or through the Contractor. Anticipated Plugging Procedure: Bottom plug: Set CIBP at 2500’ and 2sx of cement with bailer. Set CIBP at 1200’. Pressure test casing to 300 PSIG. If casing tests out, perforate at 1175’. Pump 150sx of cement down 4.5”. If no returns, pump 125sx cement down 7” X 4.5” annulus. If casing does not test out, rig up a single drum rig with 1200’ tubing and packer. Find holes and perforate at 1175’ if needed. Run tubing and packer to cement through. Will need 300sx of cement on location.