Specifications include, but are not limited to: Remove and dispose of all roofing/building materials damaged by storm. Provide and Install: a) 1819 SF of 22–24 gauge Standing Seam Metal Roofing b) 128 LF 26 Gauge Eave Trim for Metal Roofing c) 100 LF 6” gutter/downspout – box- aluminum d) 364 LF 8” Steel Purlins Z-Shape e) 1555 SF 4” Vinyl Faced/Laminated Insulation f) 290 LF 1” Rigid Conduit g) 30 SF 12” x 8” x 16” Block h) Exterior light fixture i) 25 LF Wide Flange Beam of Canopy 10-1/8”d x 5-3/4”w x ¼” thick Clean Walls and Floors in Room 1 Detach and reset (12) 4’ Strip Lights, (3) Ceiling Fans, (2) Ceiling Hung 30,000 BTU gas space heaters in Room 1 in order to replace damaged purlins. Remove and replace exterior CCTV Camera and brackets equivalent to existing. Remove and replace exterior light fixture with LED Wall Packs equivalent to existing. Seal, Prime, Prep, and Paint Exterior – one coat.