Specifications include, but are not limited to: 5.1 Women’s Restroom (Approximately 9’X11’, 99 sq. ft.) 5.1.1. Remove existing door, patch opening with 8’’ blocks to match existing.; 5.1.2. Cut new opening in center of wall and install new 6’’ metal jamb and 36’’ solid birch door with closer, kick plate and handle.; 5.2 Women’s Shower Room (Approximately 11’.3”x 16’x1”, 177 sq. ft.) 5.2.1. Remove one (1) block divider wall between showers to make two (2) showers, with one (1) ADA handicap accessible.; 5.2.2. Remove concrete ledge on floor.; 5.3 Women’s Hall (Approximately 5’x13’, 65 sq. ft.) 5.3.1. Remove existing ceiling tile and grid and replace with 2x2 aluminum grid and 2x2 vinyl/stipple ceiling tile.; 5.3.2. Remove existing light fixture and install one (1) 2x2 lay in LED light.; 5.4 Men’s Restroom (Approximately 10’x12, 120 sq. ft.) 5.4.1. Remove existing door and cut out and install 36’’ metal jamb and 36’’ solid birch door with kick plate, closer and handle.; 5.4.2. Remove existing ceiling tile and replace with 2x2 aluminum grid and standard non directional 2x2 ceiling tile.; 5.5 Men’s Shower Room, Approximately (11’1” x 16’, 177 sq. ft.) 5.5.1. Remove one (1) block divider wall between showers to make two (2) showers, with one (1) handicap ADA accessible.; 5.5.2. Remove concrete ledge on floor.; 5.6 Men’s Hall (Approximately 5’x13’, 65 sq. ft.) 5.6.1. Remove existing ceiling tile and grid and replace with 2x2 aluminum grid and 2x2 vinyl/stipple ceiling tile.; 5.6.2. Remove existing light fixture and install one (1) 2x2 lay in LED light;