Specifications include, but are not limited to: Currently the system consists of approximately 82 gas wells, 20 below grade condensate sumps, 16 perimeter probes, and a fla re station consisting of one Perennial Energy flare and its associated appurtenances. Gas wells are constructed with high density polyethylene or PVC Pipe surrounded by gravel, soil and waste in place. The system is primarily made up of HDPE pipe. (A diagram of the existing lateral and header network is provided in APPENDIX A). The flare station consists of two blowers, an enclosed ground flare and electrical controls. The ground flare is 8.5 ft. internal diameter, 30.66 ft. in height. The flare has the capacity of 2000 cfm of landfill gas. The control panel houses all electrical controls including emergency cut-off switch, main disconnect, etc. Additional components include condensate injections and a separate condensate leach field system, compressor skid.C.The City of Glendale currently contracts this service on a short term (annual) basis.