Specifications include, but are not limited to: The structure is a steel and metal insulated panels with concrete accents. The new overhead door location will require knowledge of a structural steel insulated panels to properly cut out, reinforce the opening, and install a new overhead commercial door. The overhead door location has CMU block feature that will need to be cut and removed. A portion of the concrete slab may need repair or replacement where the CMU need to be demoed for the new opening. The entry threshold will be a smooth transition from the asphalt to the interior concrete slab. The door is 14’-7” x 16’ tall R16 insulated panel metal door, direct drive opener, and safety systems. The work includes all trades necessary to install a fully functioning overhead door to match existing overhead doors appearance. To include all necessary electrical, framing, custom metal trim and flashing, insulated paneled door, electric direct drive opener with remote, and all associated safety equipment.