Specifications include, but are not limited to: FOOD SERVICE AREAS a. Bait gels for cockroach control shall be used. When applied, baits shall be rotated to limit resistance. b. Boric acid shall be used in voids at least every 6 months. c. A growth regulator shall be applied at least quarterly. d. A sanitation report shall be completed monthly detailing the conditions found in the food service areas NON FOOD SERVICE AREAS a. Each building shall have a sighting log at a designated location for monthly inspection by the Contractor. b. All floors of every building shall have insect monitors installed as part of the service. These insect monitors shall be inspected monthly. c. Each building listed herein shall have an exterior treatment each month. An exterior ant bait station shall be placed on each side of all buildings serviced and inspected monthly.