Specifications include, but are not limited to: Install (2) MCE Model 4000 or the equivalent. The equipment shall be non-proprietary. Repair parts shall be delivered overnight and the manufacturer shall offer support and 24/7 telephone support. 1. Furnish and install two (2) new MCE Motion 4000 non-proprietary microprocessor controller systems or the equivalent (This includes Fireman’s Service Phase I and Phase II capabilities). 2. Furnish and install new hoist way wiring to all hall and car terminals including every limit switch. 3. Furnish and install new fixtures a. Furnish and install two (2) innovation prestige model car-operating panels (COP) or equivalent in elevator cars. The ADA compliant COP will include: a digital position indicator with voice enunciation, illuminated push buttons identified with Braille, emergency lighting, and code required fire service key switches. b. Furnish and install two (2) ADA phones. c. Furnish and install new car riding lanterns. d. Furnish and install TWO (2) new alarm bells. e. Furnish and install new landing fixtures at each floor. f. Furnish and install new hall push button stations. g. Furnish and install new jamb Braille to meet ADA requirements. 4. Furnish and install TWO (2) new pit switches. 5. Furnish and install TWO (2) new emergency rope brakes. 6. Furnish and install TWO (2) GAL door operators. 7. Furnish and install TWO (2) new A/C motors. 8. Furnish and install new car top inspection stations. 9. Furnish and install new hoist way limits.