Specifications include, but are not limited to: UNIT “A” 1) Internal Pump Station Guide Rods shall be of Stainless Steel 2) Pumps shall have Thermo and Moisture Sensors 3) Bidder shall have a minimum of Eight (8) Wastewater Pump Installations within the City of Alabaster’s Wastewater Collection System. 4) All UNITS shall have a minimum Seven [7] Year Prorated Warranty 5) Three (3") UNIT shall be able to pass 3" Spherical Solids 6) Ten (10") UNIT •Shall be Class 1/Division 1; UNIT “B” 1) UNIT “B” shall include all necessary appurtenances, which might normally be considered a part of the complete electrical system for the operational installation of the companion UNIT “A”. All of the automatic control equipment is to be supplied by one manufacturer. It shall be factory assembled, wired and tested, installed and covered by complete electrical drawings and instruction. 2) All wiring shall have not less than 600-volt insulation and all power wiring and bus shall be in complete conformity with the National Electric Code and state and local and NEMA Electrical Standards. Control wiring shall be color coded. All job connections required to conveniently replace control components shall be made at approved type terminal blocks with engraved Bakelite marker strips or similar approved means.