Specifications include, but are not limited to: Materials 1 Conductors: OFHC Copper, ½ to ¾ hard 2 Cooling Tube: 300 series stainless Steel (UW Provided) 3 End Caps: G10 phenolic plate (UW Provided) Insulation System (See Drawing 3) 1 Around Conductors: Single Layer of Trivoltherm GKG 5025, or equivalent. Seam along outside long axis (See Trivotherm PDF) 2 Between Conductors: insulating shim, 0.25mm ± 0.1mm Thickness chosen to reduce play while maintaining conductor contact with cooling tube. Extend axially 5mm past conductors. In contact with cooling tube wrap, extending radially to conductor wrap 3 Cooling Tube: Single half lapped layer of Trivoltherm GKG 5025, or equivalent 4 Outside: Single half lapped layer of 0.25mm thick glass tape