Specifications include, but are not limited to: 2. System description: a) Frame: Heavy-duty structural plate steel frame. b) Construction: Cabinet front, top, sides and inner and outer tubs, 304 grade stainless steel, ASTM A 666. c) Input Voltage: 480-volt, 3-phase, 60 hertz, three (3) wire plus ground. d) Dry weight capacity: 200-pounds, minimum. e) Cylinder diameter: 42 inches, minimum. f) Cylinder depth: 37.5 inches, minimum. g) Cylinder volume: 30.1, cubic feet minimum. h) Overall width: 46.1 inches, minimum. i) Overall height: 72.6 inches, minimum. j) Overall depth: 67.5 inches, minimum. k) Door opening size: 24 – 13/16”, minimum. l) Door bottom to floor: 30.5 inches, minimum m) Steam connection: three-quarter (0.75”) inch. n) Number and size of water connections: two (2) main fill connections with one (1”) inch NH male connections and two (2) spray rinse connections with three-quarter (0.75”) inch NH male connections. o) Number and size of drain outlets: Two (2) outlet at three (3”) inches. p) G Force 200 q) Overflow: Internally plumbed. r) Control system: Programmable microprocess. s) Cylinder drive: Inverter drive, poly V belt system. t) Drive motor: Ten (10) horsepower, minimum. 3. Performance requirements: a) Number of selectable speeds: nine (9. b) Number of selectable extract speeds: five (5), minimum. c) Revolutions per minute (RPM): i. Gentle: 26 RPM, minimum. ii. Wash: 36 RPM, minimum. iii. Distribution: 65 RPM, minimum. iv. Very low extract: 213 RPM, minimum. v. Low extract: 366 RPM, minimum. vi. Medium extract: 410 RPM, minimum. vii. High extract: 458 RPM, minimum. viii. Very high extract: 502 RPM, minimum. ix. Ultra-high extract: 579 RM, minimum.