Specifications include, but are not limited to: 1. Each track geometry testing measurement sequence will generate real time electronic chart recording and real time hard copies of the chart recording for each parameter and exception report listing defects. 2. Exception reports shall include: start location, stop location, total defect length, defect classification per APTA RT-SF-S-002-02,Rev.1, maximum deviation location, maximum deviation in inches, exceptional threshold in inches, class of track, tangent or curve location. PC’s and PT’s shall be distinguishable on graphs. Parameter Range Tolerance A. Track Gauge 55-59 Inches +/- 0.03125 Inches B. Profile-both rails 5 Inches +/- 0.03125 Inches C. Alignment-both rails 6 Inches +/- 0.0625 Inches D. Track Level & Elev. 7 Inches +/- 0.03125 Inches E. Track Twist 5 Inches +/- 0.0625 Inches F. Speed +/- 0.25 MPH G. Location +/- 1 Foot H. Curvature +/- 15 Minutes