Specifications include, but are not limited to: The Monthly Inspection & PM Service for each of the two (2) elevators shall: Occur monthly and the Contractor shall contact the VIB Contract Administrator at least 24 hours in advance of each PM Inspection to schedule the PM Inspection; Include at minimum the preventative maintenance as recommended by the manufacturer for the elevator detailed in this IFB; Include manufacturer required testing and inspection, calibration and/or other work necessary to maintain the equipment in continuous operating condition; As a part of PM, the Contractor shall examine all safety devices and governors and shall conduct an annual no-load safety test every March. This no-load safety test shall be provided based upon the contract monthly PM fee; All inspections shall be made in accordance with the procedures established in the ANSI/ASME A17.2 and reported on the appropriate inspection and test checklist for each type of elevator; and The Contractor shall repair or replace, if needed, the following: machine worm gear, thrust bearings, drive sheave shaft bearings, brake pulley, brake coil, brake contact, brake linings, and component parts.