Specifications include, but are not limited to: Provide turnkey system and design to attain and maintain minimum light levels of 100fc/infield and 70fc/outfield by retrofit of existing light poles with energy saving LED fixtures and associated components. o Light Level of 100 foot-candles in the infield 1.2:1 Uniformity and 70 foot-candles in the outfield 2:1 Uniformity o Minimum lumen output of 13,700,000 for entire system lighting the field o Candela (Glare of Fixture) of less than 500 at home plate from the outfield pole locations and 15,000 candela from the infield pole locations Provide detail for lighting control and monitoring system. Include details for the flexibility and ease of operation. Control system must have a central, hardwired location for operation, but should include capabilities for control through smart phone App, phone or computer. Include details for pre-programmed shows, dynamic scenes and capabilities to control specific zones. Provide engineering details for fixtures, cross arms, mounting equipment, etc… Provide the number and fixture type to achieve specified light levels of 100/70. Upon completion of project, provide verification through lighting performance audit that the 100/70 lighting standards are met. Lighting standards must be guaranteed throughout the warranty period. Provide verification of acceptable light levels throughout spectator viewing areas that rely on field lighting as the main source of lighting for safe passage. Provide details regarding light control measures and capabilities in these areas. o Light Level average of 40 foot-candles in the seats is required as a minimum. Provide demolition detail for existing metal halide fixtures and associated parts and material to be replaced. Cost should include all hauling and waste fees associated with the lighting removal.