Specifications include, but are not limited to:(1) The City of Waco has issued this solicitation for Water Transmission Line from Riverside WTP to Gholson GST (W1496). (2) The major work shall generally consist of but is not limited to all labor, materials, equipment, appurtenances and incidentals asrequired to properly install, complete and be accepted in place approximately 19,000 linear feet of 30‐inch waterline utilizing C303 Bar‐Wrapped Concrete Cylinder Pipe, an approximately 1,900 linear feet horizontal directional drilling crossing of the Brazos River utilizing HDPE piping, approximately 870 linear feet of bore and encased line under roads, 16‐inch control valve, 8‐inch surge anticipator valve, and connection to the existing Gholson ground storage tank as shown on the project drawing and as specified herein. Bid alternates will include: 30‐inch C900 PVC, 24‐inch Bar‐Wrapped Concrete Cylinder Pipe, and 24‐ inch C900 PVC. Project also includes drainage channel improvements. (3) This RFB requires prequalification of General Contractors and Horizontal Directional Drilling subcontractors. General Contractors are required to submit the questionnaire and other information set out in Appendix A, along with the prequalification application of any Horizontal Directional Drilling Subcontractor(s) the General Contractor would like the City too consider, which will then be reviewed by the City and/or its agents. Based on the criteria set out in this solicitation, bids will only be accepted from a General Contractor if said bid involves a prequalified Horizontal Directional Drilling Subcontractor. Any bid which fails to include a prequalified Horizontal Directional Drilling Subcontractor will be returned as non‐responsive.