Specifications include, but are not limited to: Diamond grind and completely vacuum 1960 square feet of flooring in our vehicle bay to a smooth dustless state to provide a superior penetration of vapor barrier coating minimizing pits and floor imperfections floor must be compatible to ASTM C722 - 18 standards for monolithic coatings. Contractor should be able to work afterhours to ensure vapor barrier has 12 hours to cure fully before applying the Build coat Of Elite Crete VB-5 at 200 SQFT per gallon. ELITE CRETE PT4 MEDIUM GRAY build coat should be added a at a rate of 75 SQFT per gallon. ELITE CRETE ECS-359 HIGH WEAR/HIGH SOLID WITH ALUMINUM OXIDE should be added at 450 SQFT per Gallon. Contractor is responsible for having valid Identification for every worker that comes to 7300 Clinton Drive you can find the requirements here https://porthouston.com/port-security/safety-and-credential-information/ Working hours are from 0800-1200 and 1300-1700 weekdays, outside of those hours or into a meal hour must be approved by the Maintenance Manager 24 hours prior to start of day. Contractor must get approval to work from the Maintenance Manager at least 72hours prior to arrival and will have 3 consecutive days to complete these repairs. Contractor must provide hookups and equipment notably generators if their equipment isn't compatible with a standard 115v/15a outlet on a 30amp circuit.