Specifications include, but are not limited to: 1200mm diameter infeed accumulation disk with tray on station Included Minimum accumulation sensor at infeed with machine stop Included 10” filter housing devices for recycled water and process air Included Sanitary pressure gauges for recycled water and process air, reading before filter Included Intermittent jetting of fresh water (WFI) and process air to reduce utility usage Included WFI sampling valve after filter Included WFI supply shut-off valve to aid in purging of WFI in pipe Included Recirculation Pump for reducing fresh water (WFI) consumption Included Recirculation water tank with amplified heating system suitable for maintaining temperature of 80 deg C Included Temperature and level sensing in recirculation water tank Included