Specifications include, but are not limited to: The Contractor shall provide all associated windstorm engineering documents, inspection fees, permit cost, supervision, labor, transportation, tools, materials and equipment necessary for the completion of the project. All work must be performed in accordance with federal, state, local building codes and OSHA safety requirements, including but not limited to IBC 2015 and Texas Windstorm Insurance Requirements. B. Repair 1. Prior to performing any work the Contractor shall obtain a siding and roof permit through the City of Corpus Christi Development Services Department. 2. The Contractor shall provide the needed materials and perform the following services: a. The Contractor shall remove and replace exterior wall metal panels and associated trim on North, South and East facing elevations with similar style and color material and install in a manner that meets windstorm requirements. b. The Contractor shall remove and replace existing metal roof and replace with a minimum 24-gauge commercial grade standing seam galvalume metal roof similar to existing color and install in a manner that meets windstorm requirements.