Specifications include, but are not limited to: 1. Contractor will furnish all labor, materials equipment, services, testing, transportation, insurance and daily expenses to meet the requirements of this Scope of Work, specifications and plans. 2. Locations provided on site maps are conceptual only. The final placement of locations is to be approved by the Opportunity Home SA Project Manager. The preferred outcome will enhance safety and security for residents. 3. Contractor will be responsible for providing electrical service to gate post bases, from the nearest building to that location. 4. Fencing and gates are to be 6ft. tall to match existing fence. 5. Contractor shall reset all posts that are leaving in the current fencing. These should be idenitifed in the proposal when submitted 6. Contractor shall install 7 concrete pads for gate operators. 7. Contractor shall install gates at 4 vehicle entries, 3 are double swing and the one by the main office is a slide gate, all are to be remote access. The gate near the office will need to remain open during business hours. 8. Contractor shall install 4 pedestrian gates with self-closing hardware and access control panel. a. Each pedestrian gate shall have screening (expanded metal) installed on inside of gate, and on latch side of the fence to prevent persons from opening gate from outside. b. Pedestrian gates should not require power. 9. Existing gate leading to bus stop on Culebra road will need keypad lock and expanded metal installed to match the new gates. 10. Contractor shall provide vandal and tamper resistant hardware and material where able. 11. Contractor will assist training Opportunity Home personnel on how to make changes to all keypad and remote control access points for adding, deleting, and reports, if available. 12. Contractor will provide a minimum of 250 remote access devices which must work with all the vehicle entry points and be programmable by Opportunity Home. 13. Fencing will need to be added from the existing fence to the new gate ranging approximately 3-10 feet depending on location. 14. Contractor will provide the wiring in conduit where required.